Comparison of the Effectiveness of Two Levels of Suction Pressure on Oxygen Saturation in ARDS Patients

  • Dadang Heryandi STIKES Abdi Nusantara & RSKD Duren Sawit
  • Sahrudi Sahrudi STIKES Abdi Nusantara
  • Artetha Mutiara Pujiantana RSKD Duren Sawit
  • Norma Norma Poltekkes Kemenkes Sorong
  • Farida Murtiani Rumah Sakit Penyakit Infeksi Prof. Dr. Sulianti Saroso
Keywords: ARDS, mechanical ventilator, oxygen saturation, suctioning

Abstract

Patients in the Intensive Care Unit (ICU) often require mechanical ventilators, necessitating close monitoring and care, including regular evaluations of oxygen saturation levels. Suction procedures are conducted in the ICU to maintain airway patency, reduce sputum retention, and prevent pulmonary infections. The effectiveness of suction procedures can vary based on the suction pressure applied, which may impact patient outcomes differently. The purpose of this study was to determine the effectiveness of suction action with pressures of 130 mmHg and 140 mmHg on increasing oxygen saturation in ARDS patients with mechanical ventilation in the ICU. The research employed a quantitative approach using a quasi-experimental pre-post design with a control group. A sample of 30 ICU patients was divided into two groups: one group of 15 patients received suctioning at a pressure of 130 mmHg, while the other group of 15 received suctioning at 140 mmHg. Oxygen saturation levels were measured using pulse oximetry before and after the suction intervention. The procedures were conducted in accordance with the hospital's Standard Operating Procedure (SOP). Data were analyzed univariate and bivariate using the T-test. There was a significant increase in oxygen saturation after suctioning with both pressures. For the 130 mmHg group, the average increase in oxygen saturation was 5.933 with a P-value of 0.000. For the 140 mmHg group, the average increase was 6.400 with a P-value of 0.000. However, there was no statistically significant difference between the two suction pressures in terms of the overall increase in oxygen saturation, with a P-value of 0.567. Both 130 mmHg and 140 mmHg suction pressures were effective in improving oxygen saturation in ARDS patients on mechanical ventilation in the ICU. Hospitals should ensure structured and consistent monitoring of suction procedures in accordance with hospital SOPs to optimize patient outcomes.

References

Butterworth, J. F., Mackey, D. C., & Wasnick, J. D. (2018). Morgan and Mikhail’s Clinical Anesthesiology (6th (ed.)). Lange Medical Book.

Chiumello, D., & Brioni, M. (2016). Severe hypoxemia: which strategy to choose. Critical Care (London, England), 20(1), 132. https://doi.org/10.1186/s13054-016-1304-7

Deli, H., Arifin, M. Z., & Fatimah, S. (2017). Perbandingan Pengukuran Status Sedasi Richmon Agitation Sedation Scale ( RASS ) Dan Ramsay Sedation Scale ( RSS ) pada Pasien Gagal Nafas Terhadap Lama Weaning Ventilator di ICU RSUP dr . Hasan Sadikin Bandung. JUrnal Riset Kesehatan, 6(1), 32–39.

Hudak, C. M., & Gallo, B. M. (2014). Keperawatan kritis pendekatan holistik (Edisi 6). EGC.

Kemenkes RI. (2019). Data dan Informasi Profil Kesehatan Indonesia 2018. Jakarta: Katalog Dalam Terbitan.

Lesmana, H. (2019). Effectiveness of suctioning and factors affecting; a systematic review. Caring: Indonesian Journal of Nursing Science, 1(2), 77–85.

Marlisa, Idjradinata, P. S., & Kosasih3, C. E. (2016). Efek Suction Melalui Catheter Mouth terhadap Saturasi Oksigen Pasien Cedera Kepala The Effect of Oxygen Supply Via Oral Catheterization in the Suction Process to the Oxygen Saturation Level in the Patient with Head Injury. Jurnal Keperawatan Padjajaran, 1(1). https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/64/61

Masikome, J. N., Laihad, M. L., & Lalenoh, D. C. (2021). Tatalaksana Acute Respiratory Distress Syndrome Pada Pasien Dewasa Dengan Steroid. Jurnal Biomedik, 13(28), 118–124. https://doi.org/https://doi.org/10.35790/jbm.13.1.2021.31797

Muhaji, Santoso, B., & Putrono. (2017). Comparison of the effectiveness of two levels of suction pressure on oxygen saturation in patients with endotracheal tube. Belitung Nursing Journal, 3(6), 693–696.

Nicholson, T. W., Talbot, N. P., Nickol, A., Chadwick, A. J., & Lawton, O. (2020). Respiratory failure and non-invasive respiratory support during the covid-19 pandemic : an update for re-deployed hospital doctors and primary care physicians. BMJ, 1–7. https://doi.org/10.1136/bmj.m2446

Özden, D., & Görgülü, R. S. (2015). Effects of open and closed suction systems on the haemodynamic parameters in cardiac surgery patients. Nursing Critical Care, 20(3), 118–125. https://doi.org/10.1111/nicc.12094

Potter, P. A., & Perry, A. G. (2015). Buku ajar fundamental keperawatan: Konsep, proses & praktik (Edisi 7). EGC.

Rekam Medik RSKUD Duren Sawit. (2024). Registrasi pasien ICU RSUD Duren Sawit.

Subhan, A. (2018). Efektifitas tekanan suction 120 mmHg terhadap kadar SPO2 pada pasien stroke di Ruang ICU RS PKU Muhammadiyah Gombong. Sekolah Tinggi Ilmu Kesehatan Muhammadiyah Gombing.

Suparti, S. (2019). Pengaruh Variasi Tekanan Negatif Suction Endotracheal Tube (ETT) Terhadap Nilai Saturasi Oksigen (SpO2). Herb-Medicine Journal, 2(2), 8. https://doi.org/10.30595/hmj.v2i2.4914

Yogasara, Y., Rakhmawati, A., Murtiani, F., & Widiantari, A. D. (2023). Pengaruh Tindakan Suction pada Perubahan Saturasi Oksigen Pasien Pneumonia. Jurnal Ilmiah Keperawatan IMELDA, 9(2), 122–127.

Yousefi, H., Vahdatnejad, J., & Yazdannik, A. R. (2014). Comparison of the effects of two levels of negative pressure in open endotracheal tube suction on the physiological indices among patients in intensive care units. Iranian Journal of NUrsing and Midwifery Research, 19(5), 473–477.

Published
2024-11-09
How to Cite
Heryandi, D., Sahrudi, S., Pujiantana, A. M., Norma, N., & Murtiani, F. (2024). Comparison of the Effectiveness of Two Levels of Suction Pressure on Oxygen Saturation in ARDS Patients. Indonesian Journal of Global Health Research, 6(S6), 93-102. https://doi.org/10.37287/ijghr.v6iS6.4655